skip to Main Content

Coating of ceilings, known as suspended ceilings, is increasingly used in all kinds of work, either new or renovation. They are easy to apply, simplify the execution of electrical installations and air conditioning, and have greater aesthetic value. According to the project and the desired insulation, we can use: simple suspended boards, with the insulation glued to the ceiling or with interposed insulation.

Application:

Mark the final position on the side walls with a finishing profile (angle support or fin). Attach and level the profile to the ceiling using, for example, threaded rod pivots. There are other ways for attaching the boards, depending on the support. Apply the boards with staggered joints.

Examples of systems:

38 BA13A Ceiling

GCDS 38/500 [13A+F530] MW

Solution for interior ceilings, consisting of a structure with PT45 horizontal metal profiles spaced every 500 mm, suspended by vertical items fixed to the ceiling, to which 1 layer of BA13A plasterboards (STANDARD) is fixed. Volcalis ALPHA mineral wool in the cavity space.

Thickness38 mm
Weight per m²10,60 kg/m²
Acoustic InsulationPercussion Sounds

Rw = 64 dB
Δ Rw = 12 dB

Itecons reference test ACU 075/11

Ln, r,w = 61 (-3) dB
Δ Lw = 17 (-8) dB

Itecons reference test ACU 076/11

75 BA13A Ceiling

GCDS 75/500 [2X13A+F530+RS] MW

Solution for interior ceilings, comprising a structure with PT45 horizontal metal profiles and Suspension Rails, spaced every 500 mm, suspended by vertical elements fixed to the ceiling, to which 2 layers of Gyptec BA13A (STANDARD) plasterboards are fixed. Volcalis ALPHA mineral wool in the cavity space.

Thickness75 mm
Weight per m²19,10 kg/m²
Acoustic InsulationPercussion Sounds

Rw = 66 dB
Δ Rw = 14 dB

Itecons reference test ACU 077/11

Ln, r,w = 57 (-4) dB
Δ Lw = 21 (-7) dB

Itecons reference test ACU 078/11

92 BA13Protect Ceiling

GCDS 92/750/500/600 [2x13Protect+2xPT60] MW

Solution for ceilings, consisting of: Cross structure with horizontal ceiling profile PT60, primary and secondary, spaced each 750 mm and 500 mm respectively, suspended by rod pivots to the ceiling, to which two layers of Gyptec PROTECT boards are attached. Volcalis ALPHA mineral wool in the cavity space.

Thickness92 mm
Weight per m²30,00 kg/m²
Acoustic InsulationPercussion Sounds

Rw = 71 dB
Δ Rw = 21 dB

Itecons reference test ACL 005/19

Ln, r,w = 54 (-6) dB
Δ Lw = 24 (-5) dB

Itecons reference test ACL 006/19

57 BA13Gold Ceiling

GCDS 57/400 [2x13Gold+(PT45+AV)] MW60

Solution for ceilings, consisting of: Cross structure with horizontal ceiling profile PT60, primary and secondary, spaced each 750 mm and 500 mm respectively, suspended by rod pivots to the ceiling, to which two layers of Gyptec BA13Gold (GOLD) boards are attached. Volcalis ALPHA mineral wool in the cavity space.

Thickness57 mm
Weight per m²26,14 kg/m²
Acoustic InsulationPercussion Sounds

Rw = 71 dB
Δ Rw = 19 dB

Itecons Value by approximation ACL 052/14

Ln, r,w = 52 (-4) dB
Δ Lw = 26 (-7) dB

Itecons Value by approximation ACL 054/14
Back To Top